ʻO Banatton IP20 UPS modular pūnaewele no ka Pūnaewele ʻIke Pūnaewele 20kva a i 300Kva

ʻO ka wehewehe pōkole:

Brand: Banatton
Wahi kumu: Kina
ʻAno: UPS pūnaewele
Helu Kumu: BNT9300-M 20~300KVA
Māhele: ʻEkolu Māhele
ʻAno hawewe: Nalu sine maʻemaʻe
Ka manawa hoʻoili: 0ms
Ka helu mana: 0.9
Kaha: 20KVA-300KVA
Palekana: pōkole-kaapuni, ma luna o nā voltages, hoʻohuli i ka pale pili
OEM/ODM: ʻAe
Hiki ke hoʻolako: 5000 Piece / Pieces i kēlā me kēia mahina
Packaging: Carton a i ʻole pahu pahu lāʻau a i ʻole e like me kāu i noi ai


Huahana Huahana

Nā ʻāpana ʻenehana

Huahana Huahana

wehewehe

Brand: Banatton
Wahi kumu: Kina
ʻAno: UPS pūnaewele
Helu Kumu: BNT9300-M 20~300KVA
Māhele: ʻEkolu Māhele
ʻAno hawewe: Nalu sine maʻemaʻe
Ka manawa hoʻoili: 0ms
Ka helu mana: 0.9
Kaha: 20KVA-300KVA
Palekana: pōkole-kaapuni, ma luna o nā voltages, hoʻohuli i ka pale pili
OEM/ODM: ʻAe
Hiki ke hoʻolako: 5000 Piece / Pieces i kēlā me kēia mahina
Packaging: Carton a i ʻole pahu pahu lāʻau a i ʻole e like me kāu i noi ai

Nā hiʻohiʻona

I kēia ao hou,Hāʻawi mana hiki ʻole ke hoʻopau ʻia (UPS)ua lilo nā ʻōnaehana i mea nui o nā ʻoihana a me nā kānaka. Hāʻawi kēia mau ʻōnaehana i ka mana hoʻihoʻi hilinaʻi i ka wā o ka pau ʻana o ka mana, e hōʻoiaʻiʻo ana e hiki ke hoʻomau i nā hana koʻikoʻi me ka ʻole o ke keakea. ʻO kahi UPS kaulana ka UPS modular.

ʻO ka UPS modular, i ʻike ʻia ʻo ia he modular uninterruptible power supply, he ʻōnaehana i haku ʻia me nā lehulehuUPSnā modules e hana pū ana e hāʻawi i ka mana hoʻihoʻi. Hāʻawi kēia ʻano UPS i nā pono he nui ma mua o nā ʻōnaehana UPS kuʻuna, e lilo ia i koho mua no nā mea he nui.

ʻO kekahi o nā pono nui o aUPS modularʻo ia kona mana hoʻopakele ikehu. Me nā helu kūpono ma mua o 96% ma 50% -75% i helu ʻia a ma luna o 95% ma 25% i helu ʻia, ua hoʻolālā ʻia kēia mau ʻōnaehana e hōʻemi i ka pau ʻana o ka ikehu. ʻAʻole kēia e hōʻemi wale i nā kumukūʻai uila akā kōkua pū kekahi i ka hana ʻana i kahi ʻōmaʻomaʻo. Eia kekahi, ʻoi aku ka nui o ka mana hoʻokomo ma mua o 0.99, e hōʻoiaʻiʻo ana i ka hoʻohana pono ʻana i ka mana, ʻoi aku ka liʻiliʻi o ka distortion harmonic total (THDi) ma mua o 3%, a maʻemaʻe a paʻa ka mana.

ʻO ka hoʻokomo ʻana i kahi UPS modular he hana ʻeha ʻole. Hāʻawi kēia mau ʻōnaehana i ka maʻalahi o ka cabling luna a lalo paha, e hoʻopau ana i ka pono no ke komo ʻana i nā keʻena uwila. Hoʻomaʻamaʻa kēia i ke kaʻina hana, mālama i ka manawa a me ka hoʻoikaika. Eia hou, me ke komo ʻana i mua, hiki ke hoʻololi maʻalahi nā mea UPS hemahema me ka wehe ʻole ʻana. Mālama kēia i ka mālama ʻana i ka makani a hoʻemi i ka manawa hoʻomaha.

ʻO kekahi pono nui o ka UPS modular ʻo ia ka maʻalahi o ka hoʻololi. Hāʻawi kēia mau ʻōnaehana i ka hoʻonohonoho maʻalahi o ka helu o nā cell bateria, e maʻalahi ke hoʻoponopono a hoʻonui i ka ʻōnaehana inā pono. Eia kekahi, i ka wā e hoʻihoʻi hou ai i nā ʻōnaehana hoʻoilina, hiki ke hoʻohana ʻia nā pākaukau kumu, e hōʻemi ana i nā kumukūʻai a hoʻonui i ka pono.

I ka wā e koho ai i kahi hoʻonā mana hoʻihoʻi pono a maikaʻi, hoʻopaʻa ʻia nā UPS modular i nā pahu āpau. ʻO kona hiki ke mālama i ka ikehu, ke kaʻina hana maʻalahi, mālama hopohopo ʻole, a me nā koho retrofit hiki ke koho mua no nā ʻoihana a me nā poʻe e ʻimi nei i kahi ʻōnaehana UPS hilinaʻi a lōʻihi.

I ka hōʻuluʻulu ʻana, ʻo UPS modular kahi hopena ikaika a maikaʻi hoʻi no ka pono o ka mana lako ʻole. Me kona mau mana hoʻopakele ikehu, maʻalahi o ka hoʻonohonoho ʻana a me ka mālama ʻana, a me nā koho retrofit maʻalahi, hāʻawi ia i ka hilinaʻi ʻole a me ka maʻalahi. Inā he ʻoihana liʻiliʻi ʻoe a he kanaka paha e nānā ana e pale i nā lako uila waiwai, ʻo ka hoʻokomo ʻana i ka UPS modular he hoʻoholo e hiki ai ke hāʻawi iā ʻoe i ka maluhia o ka noʻonoʻo a hōʻoia i ka mana ʻole i ka wā pilikia.

Kiʻi 4
ʻO Banatton IP20 UPS modular pūnaewele no ka Pūnaewele ʻIke Pūnaewele 20kva a i 300Kva
ʻO Banatton IP20 UPS modular pūnaewele no ka Pūnaewele ʻIke Pūnaewele 20kva a i 300Kva

Manaʻo liʻiliʻi

1. I ka manawa o ka palapala hoʻokō he pilikia ka mīkini, e ʻoluʻolu e kelepona i nā limahana kūʻai aku, e kuleana mākou i ka lawelawe mea kūʻai aku.
2. Ma mua o ka manawa hoʻopaʻa, ka hana kūpono ʻole a me ka pōʻino i hana ʻia e ke kanaka, e hāʻawi mau mākou i ke kōkua a me ke kākoʻo, e hāʻawi mākou i nā ʻāpana i ke kumu kūʻai.
3. E like me ka makemake o ka mea kūʻai, hiki iā mākou ke hāʻawi i nā mea maʻamau, akā hiki ke kiʻekiʻe iki ke kumukūʻai ma mua o ka mīkini maʻamau.

Nā noi

ʻO Banatton IP20 UPS modular pūnaewele no ka Pūnaewele ʻIke Pūnaewele 20kva a i 300Kva

Ke kikowaena hana ʻikepili, ʻO ka ʻōnaehana hoʻokipa, nā kikowaena kamepiula, Lapaʻau, Kaʻa, Uila, IT, ʻOihana a me nā ʻoihana ʻē aʻe.

Laina Hana Hana Hana

ʻO Banatton IP20 UPS modular pūnaewele no ka Pūnaewele ʻIke Pūnaewele 20kva a i 300Kva
ʻO Banatton IP20 UPS modular pūnaewele no ka Pūnaewele ʻIke Pūnaewele 20kva a i 300Kva
ʻO Banatton IP20 UPS modular pūnaewele no ka Pūnaewele ʻIke Pūnaewele 20kva a i 300Kva

Hoʻopili ʻia

ʻO Banatton IP20 UPS modular pūnaewele no ka Pūnaewele ʻIke Pūnaewele 20kva a i 300Kva

  • Mua:
  • Aʻe:

  • HOIKE BNT990-M BNT9150/180-M BNT9300-M
    Kaha i koho ʻia Kaha Kuhina 20-90kVA / 20-90kW 25-150kVA / 25-150kW 30-180kVA / 30-180kW 30-300kVA / 30-300kW
    Hookahi Ppwer Module Kapaa 20kVA /20kW, 25kVA /25kW,30kVA /30kW
    MAX. Mana Module NO. 3 5/6 10
    INPUT
    Komo Nui Voltage Nominal (Vac) 380/400/415
    Māhele Voltage(Vac) 138~485Vac;305~485Vac haawe,138~305Vac haawe
    Māhele 3-phase in / 3-phase out
    Ka pinepine inoa (Hz) 40-70
    Mea Mana Mana ≥0.99
    Hōʻalo Harmonic (THDi) ≤3% (100% hoʻouka)
    Hoʻokomo Bypass Voltage Nominal (Vac) 380/400/415
    Māhele Voltage(Vac) 220 Vac:25%(+10%,+15%,+20%)
    230 Vac:20%(+10%+15%)
    240 Vac:15%(+10%);-45%(-10%,-20%,-30%)
    Māhele 3-phase in / 3-phase out
    Ka hele ʻana i loko ʻAE
    Bypass Back Irrigation ʻAE
    Mea Hana Hana ʻAE
    PUKA
    Voltage(Vac) 380/400/415±1%
    Mea mana 1
    Ka pinepine (Hz) ʻAno AC ±1%/±2%/±4%/±5%/±10%
    ʻO ke ʻano pākaukau (50/60±0.1%)Hz
    Ka nalu Maʻemaʻe Sinewave
    ʻAe ʻia ʻo Crest Factor 3:01
    Hoʻokaʻawale Harmonic (THDV) ≤2% (100%Linear Load);≤3% (100%Non-linear Load)
    Hoʻololi manawa(ms) 0
    Hoʻoikaika (%) 95.50%
    Hiki i ka overload 1 hola no 110%, 10 min no 125%, 1 min no 150%, 200ms no>150%
    BATTERI
    ʻO kēia manawa hoʻouka ʻia (A) 18
    Voltage Nominal ±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc
    (30/32/34/36/38/40/42/44/46/48/50 pcs)
    KA AINA
    Ka Mahana Hana 0 ℃~40 ℃
    Ka Mahana Waihona -25 ℃~55 ℃
    Haʻahaʻa pili 0~95%
    Kiʻekiʻe
    Kaulana walaʻau (dB)
    KINO
    Ana (D x W x H) mm Keena UPS 600×850×1350 600×850×1350 600×850×1550 600×850×2000
    Module 440×620×86
    Kaumaha (kg) Keena UPS 140 155/170 290
    Module 21